Cleocin I.V.

  • Generic Name: clindamycin (Cleocin I.V.)
  • Brand Name: Cleocin I.V.
Reviewed by Medsayfa.com Last updated october 15, 2024

Patient Information about Cleocin I.V.

Patients should be counseled that antibacterial drugs including CLEOCIN PHOSPHATE should only be used to treat bacterial infections. They do not treat viral infections (e.g., the common cold). When CLEOCIN PHOSPHATE is prescribed to treat a bacterial infection, patients should be told that although it is common to feel better early in the course of therapy, the medication should be taken exactly as directed. Skipping doses or not completing the full course of therapy may (1) decrease the effectiveness of the immediate treatment and (2) increase the likelihood that bacteria will develop resistance and will not be treatable by CLEOCIN PHOSPHATE or other antibacterial drugs in the future.

Diarrhea is a common problem caused by antibiotics which usually ends when the antibiotic is discontinued. Sometimes after starting treatment with antibiotics, patients can develop watery and bloody stools (with or without stomach cramps and fever) even as late as two or more months after having taken the last dose of the antibiotic. If this occurs, patients should contact their physician as soon as possible.

INSTRUCTIONS FOR USE FOR ADD-VANTAGE SYSTEM.FOR IV USE ONLY

CLEOCIN PHOSPHATE®
Clindamycin Sterile Solution for Injection, USP
in ADD-Vantage® Vial

To Open Diluent Container:

Peel overwrap from the corner and remove container. Some opacity of the plastic due to moisture absorption during the sterilization process may be observed. This is normal and does not affect the solution quality or safety. The opacity will diminish gradually.

To Assemble Vial and Flexible Diluent Container:

(Use Aseptic Technique)

Remove the protective covers from the top of the vial and the vial port on the diluent container as follows:

    1. To remove the breakaway vial cap, swing the pull ring over the top of the vial and pull down far enough to start the opening (SEE FIGURE 1.), then pull straight up to remove the cap. (SEE FIGURE 2.) NOTE: Once the breakaway cap has been removed, DO NOT ACCESS VIAL WITH SYRINGE.

 

Swing the pull ring over - Illustration

 

Pull straight up - Illustration
  • To remove the vial port cover, grasp the tab on the pull ring, pull up to break the three tie strings, then pull back to remove the cover. (SEE FIGURE 3.
  • Screw the vial into the vial port until it will go no farther. THE VIAL MUST BE SCREWED IN TIGHTLY TO ASSURE A SEAL. This occurs approximately 1/2 turn (180°) after the first audible click. (SEE FIGURE 4.) The clicking sound does not assure a seal; the vial must be turned as far as it will go. NOTE: Once the vial is seated, do not attempt to remove it. (SEE FIGURE 4.)
  • Recheck the vial to assure that it is tight by trying to turn it further in the direction of assembly.
  • Label appropriately.
Pull up to break the three tie strings - Illustration

 

Screw the vial into the vial port - Illustration

To Prepare Admixture:

    1. Squeeze the bottom of the diluent container gently to inflate the portion of the container surrounding the end of the drug vial.
    2. With the other hand, push the drug vial down into the container telescoping the walls of the container. Grasp the inner cap of the vial through the walls of the container. (SEE FIGURE 5.)
    3. Pull the inner cap from the drug vial. (SEE FIGURE 6.) Verify that the rubber stopper has been pulled out, allowing the drug and diluent to mix.
Pull the inner cap from the drug vial - Illustration

 

Pull the inner cap from the drug vial - Illustration
  1. Mix container contents thoroughly and use within the specified time.

Preparation for Administration: (Use Aseptic Technique)

  1. Confirm the activation and admixture of vial contents.
  2. Check for leaks by squeezing container firmly. If leaks are found, discard unit as sterility may be impaired.
  3. Close flow control clamp of administration set.
  4. Remove cover from outlet port at bottom of container.
  5. Insert piercing pin of administration set into port with a twisting motion until the pin is firmly seated. NOTE: See full directions on administration set carton.
  6. Lift the free end of the hanger loop on the bottom of the vial, breaking the two tie strings. Bend the loop outward to lock it in the upright position, then suspend container from hanger.
  7. Squeeze and release drip chamber to establish proper fluid level in chamber.
  8. Open flow control clamp and clear air from set. Close clamp.
  9. Attach set to venipuncture device. If device is not indwelling, prime and make venipuncture.
  10. Regulate rate of administration with flow control clamp.

WARNING: Do not use flexible container in series connections.